Identifiant pérenne de la notice : 21337868X
Notice de type
Notice de regroupement
Note publique d'information : LE REGAIN D'INTERET POUR LES PROJETS DE VEHICULES DE RENTREE SPATIAUX A ENTRAINE LA
MISE EN UVRE D'IMPORTANTS MOYENS D'ESSAI EN EUROPE, ET NOTAMMENT LA MISE EN EXPLOITATION
DE LA SOUFFLERIE A ARC F4 DE L'ONERA (FAUGA-MAUZAC). CETTE SOUFFLERIE HYPERSONIQUE
HYPERENTHALPIQUE (A HAUTE ENTHALPIE - JUSQU'A 20 MJ/KG D'AIR - ET A HAUTE PRESSION
GENERATRICES) EST UNE INSTALLATION UNIQUE AU MONDE, UTILISEE AUSSI BIEN A DES FINS
INDUSTRIELLES, QU'A DES FINS DE RECHERCHE FONDAMENTALE. LA METHODE DE TRAVAIL CONSISTE
A UTILISER DES RESULTATS D'EXPERIENCE AU SOL, POUR ELABORER UN MODELE PHYSICO-CHIMIQUE
THEORIQUE OU SEMI-EMPIRIQUE, QUI SERA A SON TOUR INTEGRE DANS LES CODES DE CALCUL.
UNE CONFRONTATION CALCUL/EXPERIENCE VALIDERA OU NON LE MODELE. CE N'EST QU'UNE FOIS
LA VALIDATION AU SOL OBTENUE QU'UNE EXTRAPOLATION SOL-VOL POURRA ETRE ENVISAGER, EXTRAPOLATION
NECESSAIRE AU DIMENSIONNEMENT AEROTHERMODYNAMIQUE DES FUTURS VEHICULES SPATIAUX. CETTE
DEMARCHE NECESSITE DONC LA MEILLEURE COMPREHENSION POSSIBLE DES PROCESSUS PHYSICO-CHIMIQUES,
ET EN PARTICULIER UNE BONNE CONNAISSANCE DE LA NATURE THERMOCHIMIQUE DE L'ECOULEMENT
EN SORTE DE TUYERE. L'OBJECTIF DE CETTE THESE EST DONC D'AMELIORER LA COMPREHENSION
DES ECOULEMENTS EN TUYERE. AU COURS DE CAMPAGNES D'ESSAIS A L'AIR ET A HAUTE ENTHALPIE
DANS LA TUYERE2 DE F4, UNE ANOMALIE A ETE MISE EN EVIDENCE DANS L'INTERPRETATION DES
RESULTATS DE MESURES EXPERIMENTALES SUR LA DISTRIBUTION PARIETALE DE PRESSION STATIQUE
ET DE FLUX SUR LES MAQUETTES GENERIQUES ELECTRE ET HYPERBOLOIDE+VOLET. A LA SUITE
DE CETTE OBSERVATION, DES MESURES DIODE LASER A ABSORPTION SPECTROSCOPIQUE (MESURE
DE VITESSE, DE TEMPERATURE DE TRANSLATION, DE CONCENTRATION DE NO/CO) ONT ETE ENTREPRISES
DANS LE JET LIBRE EN SORTIE DE TUYERE. LE NIVEAU DE TEMPERATURE DE TRANSLATION MESURE
EST DE L'ORDRE DE 2 A 3 FOIS CELUI D'UN CALCUL EN DESEQUILIBRE THERMOCHIMIQUE CLASSIQUE.
CETTE TENDANCE A ETE CORROBOREE PAR LES MESURES DE PRESSION STATIQUE PARIETALES EN
TUYERE. DANS CETTE THESE, PLUSIEURS HYPOTHESES SONT AVANCEES POUR INTERPRETER LES
NIVEAUX DES MESURES : TOUT D'ABORD DES FACTEURS ENDOGENES AU GAZ SONT ANALYSES. PARMI
EUX, LE COUPLAGE VIBRATION-RECOMBINAISON APPARAIT COMME ETANT L'UNE DES POSSIBILITES
DU PHENOMENE OBSERVE. LE SECOND FACTEUR EST UN FACTEUR EXOGENE AU GAZ LIE A LA PRESENCE
DE PARTICULES SOLIDES DE CARBONE ISSUES DE L'EROSION OU DE L'ABLATION DES PARTIES
CARBONEES CONSTITUANT LA CHAMBRE A ARC. ENFIN, CETTE THESE PRESENTE UN CODE DE CALCUL
MONODIMENSIONNEL RAPIDE, CASL (COMPUTATION ALONG THE STAGNATION LINE), DEVELOPPE DANS
LE BUT D'ACCOMPAGNER LA RECONSTRUCTION DE L'ECOULEMENT SUR LES SONDES DE FLUX DE REFERENCE
PLACEES EN SORTIE DE TUYERE. CE CODE PERMET DE RESOUDRE LES EQUATIONS DE NAVIER-STOKES
SUR LA LIGNE D'ARRET D'UN CORPS EMOUSSE POUR UN ECOULEMENT EN DESEQUILIBRE THERMOCHIMIQUE
FAIBLEMENT IONISE. SON APPLICATION EST ILLUSTREE PAR L'ETUDE D'UN CAS DE VEHICULE
DE RENTREE TRIDIMENSIONNEL (X38).